D
AquaChill Tech
A-Series 1-to-2 Seafood Water Chiller — Refrigeration Equipment — Restaurant dual-tank live seafood displays - view 1
Refrigeration Equipment

A-Series 1-to-2 Seafood Water Chiller

Flagship Dual-Circuit Monoblock Chillers — One Unit for Two Live Seafood Tanks

The Flagship 1-to-2 Seafood Water Chiller

The A-Series 1-to-2 is Delin's flagship dual-circuit seafood water chiller — a single monoblock cabinet that holds two independent refrigeration circuits, so one machine keeps two live seafood tanks at the correct temperature. Each circuit uses a pure Grade 2 titanium heat exchanger to hold the water at a precise ±0.5 °C without corroding in saltwater or leaching metal ions, and Copeland compressors run quietly around the clock. Capacities span 5.2 kW to 8.5 kW in a single 898 × 375 × 823 mm footprint.

Technical Specifications

ModelPower SupplyPowerCurrentCoolingHeatingRefrigerantWater Flow
DL-E010+010R2A-AA220V/50Hz/1Ph1700 W8.2 A5200 W5200 WR410A2.0 m³/h
DL-E015+015R2A-AA220V/50Hz/1Ph2730 W13.2 A8500 W7200 WR410A3.5 m³/h
DL-E015+015R2F-AA380–400V/3~/50Hz2690 W5.5 A8500 W8500 WR410A3.5 m³/h

Cooling capacity is rated at 30 °C water temperature and 40 °C ambient air temperature.

Available refrigerants: R134A, R404A, R407C, R410A.

Dimensions & Installation

ModelLengthWidthHeightHole Spacing (F/R)Hole Spacing (L/R)Connection
DL-E010+010R2A-AA898 mm375 mm823 mm400 mm590 mm1.5" internal
DL-E015+015R2A-AA898 mm375 mm823 mm400 mm590 mm1.5" internal
DL-E015+015R2F-AA898 mm375 mm823 mm400 mm590 mm1.5" internal

Built for Two Tanks, One Cabinet

Two tanks usually mean two machines, two footprints and two sets of wiring. The A-Series 1-to-2 puts both refrigeration circuits in one cabinet, so you save space, simplify installation and can run two tanks at independent set-points from a single supply. From a restaurant running a lobster tank and a fish tank side by side to a supermarket pair of display units, one 1-to-2 unit matches the load.

Factory-Direct Ordering

Delin HVAC is the manufacturer, not a trading company. Order the A-Series 1-to-2 direct from the factory: MOQ is 1 unit, standard models ship within 15–25 days, customized capacities within 25–40 days, and every unit carries a 12-month warranty with set-point and water-flow support from our engineers.

CEISO 9001

Quick Specifications

ModelsDL-E010+010 / DL-E015+015 (R2A & R2F)
Cooling Capacity5.2kW – 8.5kW (two independent circuits)
Power Input1700W – 2730W
Power Supply220V/50Hz/1Ph or 380–400V/50Hz/3Ph
RefrigerantR134A / R404A / R407C / R410A
Water Flow2.0 – 3.5 m³/h
Dimensions (L×W×H)898×375×823mm
Connection1.5" internal thread
Heat ExchangerPure Titanium (Grade 2)
Warranty12 months

Chiller Sizing Calculator

Estimate the cooling capacity for your water volume and temperature drop.

Recommended Capacity

Enter your water volume, temperatures and cool-down time to see a recommendation.

Key Features

  • 1-to-2 dual-circuit design — one cabinet holds two independent refrigeration circuits for two tanks
  • ±0.5 °C temperature control on each circuit for live seafood display and holding
  • Pure Grade 2 titanium heat exchangers — saltwater-safe, no metal-ion leaching
  • Copeland compressor for quiet, reliable 24/7 operation
  • Single monoblock cabinet — 898 mm, no separate outdoor unit
  • 220V/50Hz single phase or 380–400V/3~/50Hz three phase
  • 1.5" internal-thread water connections

Applications

  • Restaurant dual-tank live seafood displays
  • Supermarket and wet-market seafood counters
  • Fish, shrimp, crab and shellfish holding (two independent tanks)
  • Live seafood transport and wholesale
  • Seafood processing pre-cooling

Frequently Asked Questions

What does "1-to-2" mean?
A single cabinet contains two independent refrigeration circuits, each with its own compressor and titanium heat exchanger. One unit can therefore cool two separate seafood tanks — or two temperature zones — independently, without buying two machines.
Why is a pure titanium heat exchanger important for seafood tanks?
Seafood tanks hold saltwater and brackish water, which corrode copper and steel and can leak metal ions that harm live stock. The pure Grade 2 titanium heat exchanger is inert in saltwater, resists corrosion for years, and never contaminates the water.
Which model do I need — single phase or three phase?
The DL-E010+010 and DL-E015+015R2A run on 220V/50Hz single phase; the DL-E015+015R2F runs on 380–400V/3~/50Hz three phase at a lower running current. Tell us your available voltage and tank volume and we will match the right model.
How do I choose the right cooling capacity?
The DL-E010+010 delivers 5.2kW at 2.0 m³/h for smaller tanks, while the DL-E015+015 delivers 8.5kW at 3.5 m³/h for larger heat loads. All three models share the same 898 × 375 × 823 mm footprint, so you can swap between them on the same installation.
What is the MOQ and lead time?
MOQ is 1 unit. Standard models ship within 15-25 days, and customized capacities within 25-40 days. Every machine carries a 12-month warranty.

Technical Specifications

ModelsDL-E010+010 / DL-E015+015 (R2A & R2F)
Cooling Capacity5.2kW – 8.5kW (two independent circuits)
Power Input1700W – 2730W
Power Supply220V/50Hz/1Ph or 380–400V/50Hz/3Ph
RefrigerantR134A / R404A / R407C / R410A
Water Flow2.0 – 3.5 m³/h
Dimensions (L×W×H)898×375×823mm
Connection1.5" internal thread
Heat ExchangerPure Titanium (Grade 2)
Warranty12 months

Specifications may vary based on customization. Contact our sales team for detailed technical drawings and customized solutions.

Interested in This Product?

Get detailed specifications, pricing, and lead time. Our team typically responds within 24 hours.